PTFE Insulated RTD Cable
-
Certifications
ISO 9001 : 2015 &
CE
-
Function
Transmit signal from RTD Sensor to Control Unit
-
Main Domestic Market
All India
-
Main Export Market(s)
Australia, North America, Eastern Europe, Middle East, South America, Western Europe, Africa, Central America, Asia
-
Material
PTFE Insulion
-
Minimum Order Quantity
100
-
Packaging Details
100 Mtrs. / 200 Mtrs. coil
500 Mtrs. on plastic spool
1000 Mtrs. on wooden drums
-
Product Type
PTFE Insulated RTD Extension Wire
-
Sample Available
Yes
-
Sample Policy
Free samples are available
-
Unit of Measure
Meter/Meters
-
Usage
Use to manufacture RTD Sensors & as extension wires for RTD Sensors
RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8,9 cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.
ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL - W - 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.
HV TEST
GRADE | SPARK TESTING | DIE ELECTRIC TESTING |
ET (250 V) | 2500 V AC | 1500 V AC |
E (600 V) | 3400 V AC | 2000 V AC |
EE (1000 V) | 5000 V AC | 3000 V AC |
APPLICATIONS | PRODUCT FEATURES |
RTD Sensors & Extension Wires | Continuous use up to 260 C |
RTD Autoclave | Single exposure up to 400 C |
Medical Instruments & Scientific Equipment | Inert to most chemical & fluids |
Sensors, Load Cells & Pressure Transducers | Unaffected by lubricants |
Electronics & Communication Equipment | Flame Retardant |
Process Instrumentation | Immune to agene fungus & water absorption |
Packaging | Resistant to gamma radiation |
PRODUCT SPECIFICATIONS: |
Conductor | Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL W - 16878 & JSS 51043, Refer Table for most popular & standard wire sizes. |
Core Insulation | PTFE Tape Wrapped & Sintered |
No. of Cores | 2, 3, 4, 6, 8 or even more |
Construction | Cores twisted |
Outer Sheath | PTFE Tape Wrapped & Sintered |
Color Coding | Confirms to EN 60751 |
Other sizes in SWG and also different construction in other stranded sizes are available on request
Optional Nickel Plated Copper Conductors
FEW POPULAR RTD CABLE WIRE SIZES as per MIL W 16878
Sr. No. | Size in AWG | No. of strands/dia. of each strand (mm) | Parameters of conductor (Nominal) (As per JSS 51034) | Nominal Dia. of Insulated Wire |
Dia. (mm) | Cross section (sq. mm) | Resistance Ohm/km at 20 C | Elongation % (Min) | ET (250 V) AC | E (600 V ) AC | EE (1000 V) AC | |
1. | 26/7/34 | 7/0.16 | 0.48 | 0.1409 | 133.7 | 9.0 | 0.79 | 0.99 | 1.24 | |
2. | 24/7/32 | 7/0.2 | 0.60 | 0.2270 | 83.2 | 9.0 | 0.91 | 1.12 | 1.37 | |
3. | 24/19/36 | 19/0.13 | 0.63 | 0.2407 | 80.2 | 9.0 | 0.91 | 1.12 | 1.37 | |
4. | 22/7/30 | 7/0.25 | 0.75 | 0.3547 | 52.5 | 13.5 | 1.07 | 1.27 | 1.52 | |
5. | 22/19/34 | 19/0.16 | 0.80 | 0.3820 | 49.8 | 9.0 | 1.07 | 1.27 | 1.52 | |
6. | 20/7/28 | 7/0.32 | 0.97 | 0.5630 | 33.0 | 13.5 | 1.27 | 1.47 | 1.73 | |